Product/Service


Calibration Sources for Radiometry and Spectroscopy

Source: TELOPS
Our three calibration sources for radiometry and spectroscopy are primarily used for field and lab applications, vacuum based applications, and field applications where two IR references are needed.
Details

Our three calibration sources for radiometry and spectroscopy are primarily used for field and lab applications, vacuum based applications, and field applications where two IR references are needed.

Click Here To Download:
Datasheet: Reliability In Radiometric Calibration

IR-VCS
IR-VCS systems are lightweight and compact calibration sources specifically designed for vacuum based applications. The standard hardware interfaces make the target easy to setup and use.

Key Benefits

  • Vacuum compatible materials
  • Excellent thermal management
  • Minimal outgassing
  • Pyram™ (1.2.4) surface geometry
  • High Emissivity > 0.99
  • Absolute temperature control
  • 77 - 800K operating range (Lower temperature range is available upon request)

Applications

  • Vacuum chamber characterization
  • Radiometry
  • Radiometric Spectroscopy

IR-PCT
The IR-PCT systems are lightweight, compact calibration sources. Ideal for field or lab applications, the standard hardware interface makes the calibration source easy to set up and use.

Benefits

  • Compact and portable for field use
  • Pyram™ surface geometry
  • High Emissivity > 0.99
  • Absolute temperature control
  • EIA-485 data link for computer control
  • Many sizes available
  • Input power 90-264 volts

Applications

  • Radiometry
  • Radiometric Spectroscopy

Specifications

Parameters Unit Value
Temperature Range °C 0-100
Temperature Setting Relative to Ambient K -15 to +80
Temperature Stability mK 25
Set Temperature Resolution mK 10
Reading Temperature Resolution mK 10
Spatial Uniformity K 0.1
Cavity Emissivity   >0.99
Surface Geometry   Pyram™
Cavity Aperture (diameter) mm 50/100

Click Here To Download:
Datasheet: IR-PCT (Infrared Portable Calibration Target)

IR-DACS
The IR-DACS system is a lightweight and compact calibration system specifically designed for field applications where two IR references are needed. The standard hardware interfaces make the system easy to setup and use. The IR sources are sealed when on park position, protecting them from the environment and increasing both the spatial uniformity and the temperature accuracy.

Key Benefits

  • Two independent IR sources
  • Full automated control of both sources
  • Compact and portable for field use
  • Pyram™ (1.2.4) surface geometry
  • High Emissivity > 0.99
  • Absolute temperature control
  • RS232 data link for computer control
  • Completely integrated control electronics
  • Works off 28V DC battery
  • Optional 120V AC to 28V DC adapter

Applications

  • Two-Point Calibration
  • Radiometry
  • Radiometric Spectroscopy

Specifications

Parameter Unit Value
Temperature Range K Ambient -15/+40
Absolute Temperature Accuracy K 0.175
Temperature Stability mK 25
Set Temperature Resolution mK 10
Reading Temperature Resolution mK 1
Spatial Uniformity K 0.1
Cavity Emissivity   >0.99
Surface Geometry   Pyram™
Cavity Aperture (each in. 3

Click Here To Download:
Datasheet: IR-DACS (Infrared Dual Automated Calibration Sources)


Need More Information? Just Ask.
Click the button below to directly contact the supplier. Use it to:
  • Ask a question.
  • Request more detailed information or literature.
  • Discuss your current project/application.
  • Request a quote.
  • Locate a distributor in your area.
  • Schedule a demo.

TELOPS

More From TELOPS

Please wait... busy