High Speed NIR Line-Scan Detector: Xlin Detector Series

Source: Xenics
The Xlin High Speed NIR Line-Scan Detector series features a line rate of 40 kHz and a resolution of 512 or 1024 pixels in combination with 12.5 µm pitch. This unique set of features enables more accurate inspection and smaller particle detection at short wavelengths making the Xlin detector ideal for high-speed imaging applications in machine vision and spectroscopy.
Details

Click Here To Download:
High speed NIR Line-Scan Detector: Xlin Detector Series Datasheet
Remote Sensing Application Note

There are three resolution offerings of 512, 1024 and 2048 pixels at different pixel formats ranging from the smallest in the world of 12.5 x 12.5µm2 to 25 x 250 µm2 rectangular pixels. Due to their high sensitivity and quantum efficiency these high speed line-scan detectors operate at very low illumination levels. The high line rate of 40 kHz (1024 pixels version) and 10 kHz (2048 pixel version) enables a high resolution in the time domain.

The sensors come in a hermetically sealed package with anti-reflective coated windows. The high-resolution InGaAs linear 512, 1024 and 2048 pixel sensors are a hybrid assembly of an array of InGaAs photodiodes equipped with a novel fourth generation multiplexer and can be delivered with an optional 3-stage Thermo-Electric cooler, resulting in a further reduction of the dark current. You can choose from various configurations between High Sensitivity mode (HS) and High Dynamic Range (HDR) mode in order to optimize your performance.

Xenics offers a wide variety of linear detector arrays for line-scan imaging and for spectroscopy applications. The linear sensor is a hybrid assembly of an array of InGaAs photodiodes connected to a charge amplifying multiplexer. The device is equipped with a novel third generation multiplexer that reduces further dark current of the device. The sensor comes in hermetically sealed packages with anti-reflection coated windows.

High speed NIR line-scan detectors - Xlin detectors Key Benefits:

  • InGaAs detector
  • 0.9 to 1.7 µm sensitivity
  • High-speed Frame rate 40 kHz or 10 kHz (2048 version)
  • Best signal-to-noise performance
  • Optional TE3 cooling for low-light-level spectroscopy
  • High sensitivity
  • Unique combination of high resolution with smallest pixel pitch of 12.5 µm

The Xlin detector allows for more accurate inspection and smaller particle detection at short wavelengths making these high speed NIR line-scan detectors appropriate for use in following applications:

Applications:

Click Here To Download:
High speed NIR Line-Scan Detector: Xlin Detector Series Datasheet
Remote Sensing Application Note


Need More Information? Just Ask.
Click the button below to directly contact the supplier. Use it to:
  • Ask a question.
  • Request more detailed information or literature.
  • Discuss your current project/application.
  • Request a quote.
  • Locate a distributor in your area.
  • Schedule a demo.

Xenics

More From Xenics

Please wait... busy