X100-7 Detector for Gamma Radiation

Source: First Sensor AG
First Sensor announces the new large area, low capacitance, and low noise X100-7 detector for gamma radiation. Based on First Sensor's low dark current and low capacitance silicon photodiode series, the new X100-7 detector has an active area of 100 mm² providing a large cross section for radiation detection. A special black epoxy encapsulant guaranties the blocking of light while maintaining small gamma ray attenuation. The X100-7 is offered in a ceramic SMD package as well as a ceramic 2-pin THD package in sample quantity up to high volume production. Applications include Ionizing radiation detector, medical equipment and personal dosimeters.
Details

Order #
Chip
Package
Active Area Size (mm) Dark
Current
Capacitance (pF) Gamma-Energy
Eγ (KeV)
Scintillator
CsJ (TI)
γ-Fenster³ Ø (mm) Datasheet
501401
X100-7
LCC10
10x10 5 80 >5 no Black Epoxy Download
501400
X100-7
CerPin
10x10 5 80 >5 no Black Epoxy Download

*Active Area = 100 mm²

Recent nuclear events have raised awareness of risks from nuclear radiation and created a demand for commercial as well as personal radiation detection devices. Nuclear radiation meters based on silicon solid state detectors such as the X100-7 provide a reliable and inexpensive solution for radiation monitoring.

High performance solid state radiation detectors use the conversion of nuclear radiation into visible light by a costly scintillator crystal. However, inexpensive detectors rely on direct absorption in the silicon.

Since the probability of direct absorption of such gamma energies in silicon is relatively low, large area, low capacitance and low noise detectors such as the X100-7 are essential.

First Sensor offers the X100-7 both in a ceramic SMD package as well as a ceramic 2-pin THD package in sample quantity up to high volume production. Custom specific options including thicker silicon, fully depletable chip designs or scintillator coupled devices are available upon request. Please contact us for further details.

Features

  • 100 mm² PIN detector
  • Light blocking encapsulant
  • Low dark current
  • Low capacitance
  • High shunt resistance
  • High sensitivity

Applications

  • Ionizing radiation detector
  • Medical equipment
  • Personal dosimeter

More information on First Sensors complete line of Detectors for Ionizing Radiation.


Need More Information? Just Ask.
Click the button below to directly contact the supplier. Use it to:
  • Ask a question.
  • Request more detailed information or literature.
  • Discuss your current project/application.
  • Request a quote.
  • Locate a distributor in your area.
  • Schedule a demo.

First Sensor AG

More From First Sensor AG

Please wait... busy